ITC 2000-S/SP1 ITC 2000-S/SP2 ITC 4000-S 电流传感器
ITC2000-S和ITC4000-S系列电流传感器
类误差R(铁路)电流测量4000的武器
主要特点:
测试电流4000A非线性测量
闭环磁通门
测量范围:6000的APK
整体误差:+ / - 0.05% + 25 C°IPN
整体误差(+ 23°C):
电源:+ / - 21.6 + / - 26.4 V
工作温度范围:-40~+85°C
模拟电流输出:0.8和1.6“IPN为2000和4000A
5年保修
减小的尺寸和低功率损耗
Class accuracy R (Railway) current measurement up to 4000 ARMS
Main characteristics:
· Non-invasive measurements of currents up to 4000 ARMS
· Closed loop Fluxgate technology
· Measuring range: up to 6000 ApK
· Max overall accuracy: +/- 0.05 % of IPN at +25°C
· Class 0.5 R according to EN50463
· Max overall accuracy (+23°C):
§ +/- 0.2% of reading @ 10 % of IPN
§ +/- 0.4% of reading @ 5 % of IPN
§ +/- 2% of reading @ 1 % of IPN
· Power Supply: +/- 21.6 to +/- 26.4 V
· Operating temperature range: -40 to +85°C
· Analogue current output: 0.8 & 1.6 A @ IPN for ITC 2000 & 4000 respectively
· 5 year warranty
· Reduced size & low power losses
Features:
· DC, AC, pulse currents high accurate measurements with high galvanic isolation (isolation test voltage: 14 KVRMS / 50Hz / 1 min)
· Aperture of 63 mm & 102 mm diameter for ITC 2000 & 4000 respectively
· Really low current consumption: 150 mA & 300 mA @ IPN for ITC 2000 & 4000 respectively
· Current overload: 100kA/100ms
· Fast response time: 0,1μs
· Large bandwidth: up to 80 KHz (3dB)
· Low temperature drift of accuracy
Standards compliance:
· EN50155 for traction applications such as:
§ On-board energy meters
§ Propulsion converters
· EN 50124-1: Insulation levels & safety
· NFF 16101/2: Fire and smoke classification
· European Directive EMC 2004 / 108 / EEC : CE Marking
· EN 50121-3-2: Railway EMC standard (Emission & susceptibility)
· EN 50463: On-board energy measurement
· EN 61010-1: Safety
· Developed and produced according International Railway Industry Standards (IRIS)
Remarks:
· New innovating patented technology for small current consumption
· Modular approach for easy adaptation for secondary connections
· Test winding as self test function
· Logic additional output as indication of the transducer state
· ITC 2000 is proposed in a split construction with the measurement head in a case and the measurement circuitry mounted remotely in a metal enclosure
|
Product search results |
|||||||||
Model |
Primary |
Measuring |
Secondary |
Supply |
Accuracy (%) |
Mounting |
|
|
|
|
|
||||||||
ITC 2000-S/SP1 |
2000 A |
3000 A |
800 mA |
24-24 Bi |
0.05 |
Panel |
|
|
|
ITC 2000-S/SP2 |
2000 A |
3000 A |
800 mA |
24-24 Bi |
0.05 |
Panel |
|
|
|
ITC 4000-S |
4000 A |
6000 A |
1600 mA |
24-24 Bi |
0.05 |
Panel |
|
|
|